Advertisement

NEDOCS calculator

Calculate the National Emergency Department Overcrowding Score from one department snapshot.

Calculator

NEDOCS score
105.42

Advertisement

How this calculator works

Capacity ratios, ventilated patients and two different waiting-time measures enter the regression equation. Times are converted to hours. Use the definitions in the original study; a current longest waiting-room wait is not the last bedded patient's door-to-bed time. The raw score is retained without clamping to 0 or 200. The result is an estimate for information only and is not medical advice.

Formula

NEDOCS = -20 + 85.8(P/B_ED) + 600(A/B_hospital) + 13.4V + 0.93T_admit + 5.64T_bed. P is the ED treatment-space census including overflow, A admitted patients still in ED, V ventilated patients, and T values are hours.

Worked example

40 patients, 40 ED beds, 400 hospital beds, 10 admitted patients, one ventilated patient, a 6-hour longest admitted stay and 1-hour last door-to-bed wait give -20 + 85.8 + 15 + 13.4 + 5.58 + 5.64 = 105.42.

Advertisement

Frequently asked questions

Which waiting time has coefficient 5.64?

The door-to-bed wait of the last patient moved to a treatment bed. The longest ED stay among admitted patients uses 0.93.

Should I enter all critical patients as ventilators?

No. This implementation uses the mechanical-ventilator variable in the published equation. A local substitute changes the model.

Does this predict my personal wait?

No. It describes department crowding and was developed in academic emergency departments. Local operations affect its usefulness.

Sources