Vapour pressure deficit calculator

Compare the moisture in air with saturation at the air or leaf temperature. Choose one humidity measurement method.

Calculator

Air vapour pressure deficit
1.2671
Actual vapour pressure
1.9007
Relative humidity
60.0000%
Dew point
16.6956

Advertisement

How this calculator works

The FAO saturation-vapour-pressure equation estimates vapour pressure over liquid water. Actual vapour pressure comes from relative humidity, dew point, or the FAO coefficient 0.000662 per C for an aspirated psychrometer. Air VPD is saturation pressure at air temperature minus actual pressure. Leaf VPD instead uses the leaf temperature; a negative leaf VPD indicates possible condensation. Below freezing, this calculation remains referenced to liquid water rather than ice.

Formula

es(T) = 0.6108 × exp[17.27T/(T + 237.3)] kPa, with T in C. ea = RH × es(Tair), or es(Tdew). Wet bulb: ea = es(Twet) - 0.000662 × P × (Tair - Twet). VPD = es - ea.

Worked example

At 0 C, es = 0.6108 kPa. With 50% relative humidity, air VPD is 0.3054 kPa. If dew point, air and leaf are all 0 C, both VPD values are zero.

Advertisement

Frequently asked questions

Can leaf VPD be negative?

Yes. A leaf colder than the dew point has saturation pressure below the actual vapour pressure of the air.

Does any wet-bulb thermometer work?

The implemented FAO coefficient assumes a ventilated Asmann-type psychrometer. Natural or unventilated instruments require a different coefficient.

Which VPD should I target?

Crop stage, species and temperature affect a suitable target. This tool calculates the physical quantity and does not prescribe a universal range.