Insulation calculator

Calculate one-dimensional thermal resistance through layers in series. Use manufacturer conductivity data for each actual product.

Calculator

Total RSI (m^2 K/W)
2.5000
Total US R-value (ft^2 h F/Btu)
14.1957
U-value (W/(m^2 K))
0.4000
First layer thickness
0.1
Thermal resistance by layer
LayerThickness (mm)RSI (m^2 K/W)US R-value
Example insulation - enter product data100.000002.5000014.19566

Advertisement

How this calculator works

For a homogeneous layer, thermal resistance is thickness divided by conductivity. Resistances add in series; the reciprocal gives U-value. Add surface films or evaluated air-space resistance separately. Framing and thermal bridges create parallel heat-flow paths that this series model does not represent.

Formula

RSI_i = thickness_i / conductivity_i; RSI_total = sum(RSI_i)+additional RSI; U=1/RSI_total; US R-value = 5.678263337 x RSI; target thickness_1 = conductivity_1 x (target RSI-other RSI).

Worked example

A 100 mm layer at 0.04 W/(m K) has RSI 2.5, US R-value 14.1957 and U-value 0.4 W/(m^2 K), before surface films.

Advertisement

Frequently asked questions

Why are there no fixed material presets?

Conductivity depends on product, density, moisture, ageing and test conditions. Enter documented data for the product being assessed.

Can I model an air gap as a solid layer?

Use an evaluated air-space resistance in the additional RSI field. Radiation and convection make thickness divided by air conductivity inappropriate.

Does this give the whole-wall R-value?

Only for a uniform series path. Studs, fasteners, junctions, compression and gaps can lower whole-assembly performance.