Refrigerant capillary tube calculator

Compare a calibrated refrigeration capillary with a nearby internal diameter using the manufacturer substitution rule.

Calculator

Replacement length
2

Advertisement

How this calculator works

Tecumseh gives a length correction for an available capillary internal diameter within 0.2 mm of the recommended diameter. The exponent is 4.5, and both diameters must use the same unit. Start with a manufacturer-supported original selection. This comparison does not determine refrigeration capacity, refrigerant charge, two-phase behaviour or operating temperatures. Tecumseh identifies roughly 1.5 to 3 m as a useful performance range and requires validation of the capillary and charge combination.

Formula

L_new = L_original (D_new/D_original)^4.5. Rearrange to recover either diameter or either length.

Worked example

Changing a 1.0 mm internal diameter to 1.1 mm with an original 2 m length gives 3.07112207 m. Keeping the diameter unchanged keeps the length unchanged.

Advertisement

Frequently asked questions

Is this a complete refrigeration design?

No. It substitutes a nearby bore around an already validated manufacturer selection.

Can I use an outside diameter?

No. Flow depends on the calibrated internal bore.

Why reject a larger diameter change?

The cited manufacturer limits this substitution rule to differences no greater than 0.2 mm.

Sources