Solar panel calculator

A solar array is sized around the electricity you use and the sun your roof receives. Enter your annual consumption, the average solar hours where you live and the panel you plan to use, and the calculator returns the array size, how many panels and what it saves.

Calculator

The daily average of peak sun hours. Canadian cities run from about 3.0 in Vancouver and St. John's to 4.2 in Regina.

The share of the panel rating that becomes alternating current after inverter, wiring, soiling and temperature losses.

Array size (kW)
9.20
Panels needed
23
Roof area needed
41.4
Generation per year (kWh)
10,208
Electricity cost avoided per year
$1,531
Emissions avoided per year (kg CO2e)
1,225
Installed cost
$18,400
Simple payback (years)
12.0
What this means
A 9.2 kW array of 23 panels generates about 10208 kWh a year, covering 102 percent of your use. It avoids about 1225 kg CO2e on the national average grid and repays its 18400 dollar cost in 12.0 years at this price. Provincial grids differ by more than ten times, so the carbon and the economics both change with location.
Array size for Canadian cities
CitySolar hours per dayArray (kW)Panels
Vancouver3.0011.4229.00
Victoria3.3010.3826.00
Calgary3.908.7822.00
Edmonton3.709.2624.00
Regina4.208.1521.00
Winnipeg3.809.0123.00
Toronto3.609.5124.00
Ottawa3.509.7825.00
Montreal3.509.7825.00
Quebec3.4010.0726.00
Halifax3.4010.0726.00
St. John's3.0011.4229.00

Advertisement

How this calculator works

A solar panel is rated at its output under standard test conditions: 1,000 watts per square metre of sunlight at 25 degrees Celsius. Real roofs rarely see that, so the usual design method counts peak sun hours, the daily average of hours at that standard irradiance. Vancouver averages about 3.0 peak sun hours over the year and Regina about 4.2, which is why the same array produces 40 percent more in Saskatchewan. The daily energy you need is your annual use divided by 365, multiplied by the share you want to cover. Dividing by the peak sun hours and by a system derate of about 0.8 gives the array size. The derate covers the inverter, wiring, soiling, snow and the fact that panels get hot and lose output. The panel count is rounded up, so the array is slightly larger than the exact target, and the roof area is the panel area times the count, before access gaps between rows.

Formula

target energy (kWh per year) = annual consumption x offset share. array size (kW) = target / (peak sun hours x 365 x derate). panels = round up(array kW x 1000 / panel watts). actual array = panels x panel watts / 1000. generation (kWh per year) = actual array x peak sun hours x 365 x derate. savings = generation x electricity price. emissions avoided = generation x 0.12 kg CO2e per kWh. payback = installed cost / annual savings.

Worked example

A house using 10,000 kWh a year, covering all of it at 3.8 peak sun hours with an 80 percent derate, needs 10,000 / (3.8 x 365 x 0.8) = 9.01 kW. With 400 W panels that is 23 panels, an actual array of 9.2 kW and an area of 23 x 1.8 = 41.4 m2. Generation is 9.2 x 3.8 x 365 x 0.8 = 10,208 kWh a year, worth $1,531 at $0.15 per kWh and avoiding about 1,225 kg CO2e. At $2,000 per kW the installed cost is $18,400, a simple payback of 12 years.

Advertisement

Frequently asked questions

Should I cover all of my consumption?

Not necessarily. Without storage, surplus power exported to the grid may earn less than you pay for power, and a smaller array often has a better payback. Many households cover 60 to 80 percent of annual use. Set the offset to model that.

Why use peak sun hours rather than the panel rating?

The panel rating is a laboratory condition. Peak sun hours fold the real weather, latitude and season into one number that you can multiply by the array size and the days in a year. It is the standard first estimate in both the PVWatts model and Natural Resources Canada guidance.

What does the derate cover?

Inverter losses, wiring, soiling, snow, shading and the temperature coefficient, which reduces output as panels warm. A clean, well-ventilated array with a modern inverter might reach 0.85; an older or partly shaded roof can be nearer 0.7.

How long do the panels last?

Most panels carry a 25 to 30 year performance warranty and still produce about 80 percent of their rated output at the end. The payback period here is financial and ignores inverter replacement, which usually happens once in that time.